ISO 17025 Gas Flow Calibration Services by Graftel

5 Business Days or Less Turnaround! 

Rotometer Calibration
Air and Gases

Laminar Flow Element Calibration

Flowmeter Calibration
Air and Gas

Rotameter calibration services. Laminar flow meter calibration services. Gas flow calibration services.

Anemometer Calibration
Thermo and Standard

Sonic Nozzle and Sonic Choke Calibration
Anemometer Calibration Services. Sonic Nozzle and Sonic Choke Calibration Services.

 

 Graftel maintains five NIST traceable primary gas flow calibration systems. Each system achieves uncertainties in the 0.2% of reading range.

Our three lowest flow rate gas systems utilize a gravimetric primary standard. Laminar flow elements are used as secondary working standards. These secondary standards are periodically verified while in use against the gravimetric primary standards.

Our two highest flow rate gas systems utilize sonic nozzles. These systems are periodically calibrated against a static gravimetric primary standard.

 

Gas Flow Calibration Services Include

 All flow calibrations completed by Graftel come with:
  • A NIST traceable and ISO 17025 accredited certificate
  • All corresponding test data
  • Unit inspection/service testing
  • 5 Business days or less turnaround

 Listed below is a small sampling of the types of equipment we can perform flow calibrations on in our labs. If you don't see your piece of equipment listed, feel free to contact us, either via email or phone at 847-398-5100.

Digital RH Meter
Analog RH Meter
Dewpoint Meter
Transducers
Velocity Meters Rotometers
Air Duct Flow Hoods
Thermal Mass Flowmeters
Laminar Flowmeters
Orifice Plates
Critical Nozzles
Controllers
Pressure Gauges to 1000psi
Turbine Meters
Positive Displacement Meters
LFE
Vortex
V-Cone
Coriolis
Ultrasonic Flow Gauges
Flow Meters
Rotometers
Anemometers
Hygrometers

Manufacturers we have Calibrated

 Graftel's labs have worked with hundreds of name brand and sometimes not-so-name brand flow meters and gauges, we specialize in working with you to keep your valuable equipment calibrated. Listed below is a a small sampling of some of the manufacturers we complete flow calibration's with on a regular basis. 
 If you don't see the manufacturer of your equipment here, don't panic!. 
 Contact us with your information and we'll take care of the rest.
Great Plains Industries
Brooks
Brooks "SMART" meters
Dwyer
Omega
Aalborg
Flow Technology
Foxboro
Panametrics
Fischer - Porter
MEM
Yokogawa
Gilmont
Flocat
Hedland
Eldridge Products
FTI
TSI
Solomat
Alnor
Sierra
Hedland
Meriam
Cosa
Schutte & Koerting
Draeger
JLC
Fox Valve
Alicat Scientific
UFM
ATC
Vaisala
Victor
Shaw
MKS Flow
Jewett
Hastings
General Eastern
Blue-White Industries
Madgetech
American Meter Company
Eqimeter
Conbraco
Kurz
Testo
Sper Scientific
Davis
Graywolf
Cole-Parmer
Fischer Scientific
Ertco
Millipore

...And MANY More!

 

Gas Primary A

 Air or any mixture of non-explosive, non-toxic gasses may be used. System flow rate is set and maintained extremely steady by up to three stages of regulation. The system’s flow rate range is 0.06 to 6 sccm, (0.00012 to 0.012 scfh). The pressure range is 0 to 1000 psig, (0 to 124 bar). The uncertainty in mass flow rate is up to 0.20% of reading.  

Gas Primary B

 Air or any mixture of non-explosive, non-toxic gasses may be used. System flow rate is set and maintained extremely steady by up to three stages of regulation. The system’s flow rate range is 3 to 140 sccm, (0.005 to 0.3 scfh). The pressure range is 0 to 1000 psig, (0 to 124 bar). The uncertainty in mass flow rate is up to 0.20% of reading.

Gas Primary C

 Air or any mixture of non-explosive, non-toxic gasses may be used. System flow rate is set and maintained extremely steady by up to three stages of regulation. The system’s flow rate range is 0.05 to 3 slm, (0.1 to 6 scfh). The pressure range is 0 to 1000 psig, (0 to 124 bar). The uncertainty in mass flow rate is up to 0.20% of reading. 

Gas Primary D

 Air or any mixture of non-explosive, non-toxic gasses may be used. System flow rate is set and maintained extremely steady by up to three stages of regulation. The system’s flow rate range is 2 to 88 slm, (4 to 186 scfh). The pressure range is 0 to 1000 psig, (0 to 69 bar). The uncertainty in mass flow rate is up to 0.20% of reading.

Gas Primary E

 Air or any mixture of non-explosive, non-toxic gasses may be used. System flow rate is set and maintained extremely steady by up to three stages of regulation. The system’s flow rate range is 23 to 1168 slm, (1 to 41 scfm). The pressure range is 0 to 1000 psig, (0 to 69 bar). The uncertainty in mass flow rate is up to 0.20% of reading.

Graftel, Inc.
870 Cambridge Drive
Elk Grove Village, IL. 60007
Ph. 847.364-2600   Fax. 847.364-2899